Calculators

Every calculator, and the standard behind it

42 calculators across 5 disciplines. Each one names the CIBSE, BS 7671, BS EN or SAP method it implements, and each run can produce a PDF report showing the inputs, the method and the governing check.

That count is the calculators available on a paid plan. It excludes unreleased calculators still in testing, and superseded pages kept reachable so existing saved sheets still open.

Electrical

Distribution design to BS 7671 and the IET On-Site Guide, plus the plant that hangs off it.

  • Circuit Design

    Sizes the cable, checks the adiabatic condition, selects the protective device and verifies earth-fault loop impedance in one pass.

    BS 7671

  • Voltage Drop

    Volt drop along a circuit from the tabulated mV/A/m figures, with the reactive term where it matters.

    BS 7671 Appendix 4

  • Fault Level

    Prospective fault current at a point in the installation, single- and three-phase.

    BS 7671 Appendix 14

  • Load Schedule

    Connected load and maximum demand for an installation, applying the tabulated diversity factors.

    IET On-Site Guide Table A2

  • DB Schedule

    Builds a distribution board schedule circuit by circuit from the load schedule.

    BS 7671 Reg 536.4.202 / BS EN IEC 61439-1

  • Motor Starter

    Contactor and overload selection for direct-on-line and star-delta starting.

    BS EN IEC 60947-4-1:2019 / BS 7671

  • Power Factor Correction

    Capacitor bank size to reach a target power factor, with the resulting kVA saving.

    BS 7671 / CTG007

  • Generator

    Generator set sizing including step-load acceptance and the resulting voltage and frequency dip.

    ISO 8528-1 / -5

  • UPS

    UPS rating and autonomy from the connected load and the required runtime.

    IEC 62040-3:2021

  • Lighting Design

    Luminaire count by the lumen method for a target maintained illuminance.

    BS EN 12464-1:2021

  • Emergency Lighting

    Escape-route, open-area and high-risk illuminance, points of emphasis and duration for an emergency scheme.

    BS 5266-1:2025 / BS EN 1838:2024

  • EV Charging

    Charge-point maximum demand, current per phase, the DNO connection route and the G98/G99 route for V2G points.

    BS 7671 Section 722

AC & Refrigeration

Cooling and heating loads by the CIBSE or ASHRAE method, and the refrigeration plant that serves them.

  • Space Load

    Room heating and cooling loads, by the cyclic admittance method or the radiant time series.

    CIBSE Guide A / ASHRAE Fundamentals

  • Solar Gain

    Solar heat gain through glazing for a given station, orientation and shading.

    CIBSE Guide A

  • Refrigeration Loads

    Cold-store load build-up: transmission, infiltration, product, and internal gains.

    IOR Cold Store CoP 2020 / ASHRAE

  • Refrigerant Pipe Sizing

    Suction, liquid and discharge lines for one circuit, by pressure loss or by velocity, with riser oil return, liquid lift and pipework charge.

    ASHRAE Refrigeration 2022 / Danfoss

  • Condensate Drain

    Condensate flow and drain size for cooling coils, with trap depth.

    CIBSE Guide G / AD H / BS EN 12056-2

  • Machinery Room

    Machinery-room ventilation and leak detection for a refrigerant charge.

    BS EN 378-3

Ventilation

Air rates, duct sizes and the pressure and noise that follow from them.

  • Ventilation Design

    Supply and extract rates for a space, by occupancy, area or air-change basis.

    CIBSE Guide A / AD F / BB101 / HTM 03-01 / BS EN 16798-1

  • Whole Dwelling

    Whole-dwelling and room extract rates for a residential scheme.

    Approved Document F Vol 1 (2026)

  • Natural Ventilation

    Opening areas and achievable flow from wind and buoyancy.

    BS EN 16798-7 / CIBSE Guide A / AD F

  • AHU Duty

    Air-handling unit duty, coil loads and heat-recovery performance.

    CIBSE Guide B3 / ASHRAE Fundamentals Ch.1 / AD L Vol 2

  • Standalone Fan

    Fan duty and specific fan power against the Part L limit, or the fan energy index.

    Approved Document L Vol 2 / CIBSE Guide B4 / AMCA 208

  • Duct Sizing

    Duct sizes by constant pressure drop or velocity, circular, rectangular or flat-oval.

    CIBSE Guide B2 / Guide C

  • Ductwork Pressure Loss

    System pressure loss along an index run, straight lengths plus the fitting catalogue.

    CIBSE Guide C

  • Duct Insulation

    Insulation thickness for heat loss, condensation control or personnel protection.

    BS 5422:2023

  • Grille

    Neck and face velocity against the CIBSE B2 envelope, and throw, for a required flow.

    CIBSE Guide B2

  • Louvre

    Louvre free area and pressure drop for intake and discharge openings.

    CIBSE Guide C

  • Duct Noise

    Breakout and regenerated noise along a duct run, to a room NR level.

    CIBSE Guide B4

Plumbing & Heating

Wet systems end to end: heat loss, heat source, distribution, storage and drainage.

  • Heat Loss

    Room-by-room design heat loss for a dwelling, with each room's radiator sized for the flow temperature.

    CIBSE Domestic Heating Design Guide 2026 / BS EN 12831-1:2017

  • Heat Source Sizing

    Boiler or heat pump output for a commercial building or a single dwelling, with combi selection and a heat pump's yearly electricity estimate.

    CIBSE Guide B1 / AM16 · CIBSE Domestic Heating Design Guide 2026 · MCS MIS 3005-D / MCS 031 a)

  • Heat Pump Noise

    Sound level at each neighbour's window from an air source heat pump, against the 37 dB(A) permitted development limit.

    MCS 020 a) Issue 1.1

  • Ground Loop Sizing

    Length of borehole, horizontal or slinky ground loop for a ground source heat pump under 30 kW.

    MCS MIS 3005-D / MGD 007

  • Underfloor Heating

    Floor output and pipe spacing against the surface-temperature limits.

    BS EN 1264-2:2021 / CIBSE Domestic Heating Design Guide 2026 / MCS MGD 007

  • Expansion Vessel

    Vessel volume and fill pressure from system volume, temperature range and pressures.

    BS EN 12828 Annex D and UK National Annex / CIBSE Domestic Heating Design Guide 2026

  • Hydronic Pipe Sizing

    Heating and chilled pipe sizes by pressure drop, or by velocity for a house.

    CIBSE Guide C / CIBSE Domestic Heating Design Guide 2026

  • Pipe Insulation

    Insulation thickness for heat loss, freeze and condensation control.

    BS 5422:2023 / CIBSE Domestic Heating Design Guide 2026

  • Cold Water Pipe Sizing

    Cold water pipe size from the design flow, checked for velocity and for the pressure left at the outlet.

    CIBSE Guide C / Guide G / BS EN 806-3

  • Hot Water Storage

    Hot water storage for a commercial building's daily demand, or a dwelling's cylinder with its coil and reheat time.

    CIBSE Guide G / CIBSE Domestic Heating Design Guide 2026 / MCS MIS 3005-D

  • Drainage

    Discharge stack size from the appliances connected, and rainwater pipe size from the roof area.

    BS EN 12056-2 and -3 / AD H

Renewables

Solar output by the MCS and SAP methods, with the connection thresholds.

  • Solar Thermal

    The MCS 024 performance estimate and fuel saving, and the SAP monthly method, for solar hot water.

    MCS 024:2025 / SAP 10.3 Appendix H / MCS MIS 3001

  • PV Sizing

    The MCS 032 standard estimate and the SAP yield, self-consumption from the MCS tables, and inverter current against the G98 and G99 thresholds.

    MCS 032:2025 / SAP 10.3 Appendix M / MCS MIS 3002

See the working before you trust it

For several of these we publish our own verification: fixed worked examples run through the same calculation code, compared line by line with the values printed in the standard, with every delta and pass or fail shown.

Read the verification pages

MEPCalc is in a closed tester phase ahead of public launch.